- using R Under development (unstable) (2024-12-17 r87446 ucrt)
- using platform: x86_64-w64-mingw32
- R was compiled by
gcc.exe (GCC) 13.3.0
GNU Fortran (GCC) 13.3.0
- running under: Windows Server 2022 x64 (build 20348)
- using session charset: UTF-8
- checking for file 'swCRTdesign/DESCRIPTION' ... OK
- checking extension type ... Package
- this is package 'swCRTdesign' version '4.0'
- checking package namespace information ... OK
- checking package dependencies ... OK
- checking if this is a source package ... OK
- checking if there is a namespace ... OK
- checking for hidden files and directories ... OK
- checking for portable file names ... OK
- checking whether package 'swCRTdesign' can be installed ... OK
See the install log for details.
- checking installed package size ... OK
- checking package directory ... OK
- checking DESCRIPTION meta-information ... OK
- checking top-level files ... OK
- checking for left-over files ... OK
- checking index information ... OK
- checking package subdirectories ... OK
- checking code files for non-ASCII characters ... OK
- checking R files for syntax errors ... OK
- checking whether the package can be loaded ... [3s] OK
- checking whether the package can be loaded with stated dependencies ... [2s] OK
- checking whether the package can be unloaded cleanly ... [2s] OK
- checking whether the namespace can be loaded with stated dependencies ... [3s] OK
- checking whether the namespace can be unloaded cleanly ... [3s] OK
- checking loading without being on the library search path ... [3s] OK
- checking use of S3 registration ... OK
- checking dependencies in R code ... OK
- checking S3 generic/method consistency ... OK
- checking replacement functions ... OK
- checking foreign function calls ... OK
- checking R code for possible problems ... [10s] OK
- checking Rd files ... [1s] NOTE
checkRd: (-1) swDsn.Rd:28: Lost braces
28 | numeric (scalar or vector): Relative treatment effect upon crossing over from control. Note that this is not the treatment effect (the treatment effect is specified in the call to other functions such as \code{swPwr} or \code{swSim})! If \code{tx.effect.frac} is set to a scalar with value of 1, the standard SW CRT treatment effect will be presumed. If code{tx.effect.frac} is set to a scalar with a fractional value between 0 and 1, then only the first time point upon crossing over from control will have fractional relative treatment effect; the remaining exposure times will have a relative treatment effect of 1. If a vector of fractional treatment effect is specified, each element of the vector corresponds to the (fractional) treatment effect upon crossing over from control; if the length of the vector is less than total number of exposure times, the remaining time points will have a relative treatment effect value of 1; if the length of the vector is greater than total number of time points after crossing over, not all elements of \code{tx.effect.frac} will be used. The default value is (scalar) 1.
| ^
- checking Rd metadata ... OK
- checking Rd cross-references ... OK
- checking for missing documentation entries ... OK
- checking for code/documentation mismatches ... OK
- checking Rd \usage sections ... OK
- checking Rd contents ... OK
- checking for unstated dependencies in examples ... OK
- checking examples ... [6s] OK
- checking PDF version of manual ... [23s] OK
- checking HTML version of manual ... [3s] OK
- DONE
Status: 1 NOTE